Features:
Completely controlled by PC, can flexibly select the flame and graphite furnace atomizer (optional).
* Integrated floated optical platform design improves the optical system shock resistance stable.
* Eight light stands can be changed automatically and preheat the eight lights meantime as well as optimize the working condition of the hollow cathode lamp.
* Position adjusting: the flame burner can be set on the best position automatically.
* Fully automated wavelength scanning and peak searching.
* Complete safety chains protection equipment: warning and automatic safety protection for the wrong burner connection, leakage of the gas, under voltage of air and the abnormal flameout.
* lamp and self-absorption background calibration.
* Measuring method: flame absorption method and emission method.
* Result printing: parameter, data result and diagram.
* Data processing: more than 500 data self-storage and cut-off storage, the analyzed result is stored in EXCEL format.
Basic Functions:
1.Photometry
Test Abs., Transmittance and Energy by fixed wavelength
2. Quantitative
Linear fit and Linear fit through zero two modes
a. Coefficient, Standard Sample input and Standard Sample read three modes to establish standard curve
b. Establish A=K1*C+K0, can search original data, graph curve, parameters settings
c. Can save 240 group curves, can test 240 data in each curve
d. Double wavelength, Triple wavelength test functions
3.Kinetics
Used for time course scanning or reaction rate calculations△A/t, can search all data.
4.Multi-Wavelength
Can test Transmittance and Abs. with 8 different wavelengths at most
5.Scanning
User can set the scan range from 190nm to 1100nm to test the max. Abs. peak value, can do derivation, arithmetical operationsto the graph.
6.Biology
6 methods: DNA/Protein, UV, Lowry, BCA,CBB and Biuret
Model |
BK-AA4530F |
Wavelength Range |
190~900nm |
Spectral Bandwidth |
0.1, 0.2, 0.4,1.0 and 2.0nm |
Wavelength Accuracy |
≤±0.15nm |
Wavelength Repeatability |
≤0.04nm |
Base Line Stability |
≤0.002A/30min (Cu) |
Characteristic Concentration |
0.02μg/ml/1% (Cu) |
Detection Limit |
0.004μg/ml (Cu) |
Preciseness |
≤0.5% |
Grating |
1800 lines/mm |
Inflamer |
All-metal titanium burner |
Atomizer |
Effective glass atomizer |
Lamp Stand |
8 |
D2 background Calibration |
When the background is 1 A, the background ability should be deducted not less than 50 times; self absorption background deduction method |
Power Supply |
220V, 50Hz |
Packing Size(W*D*H) mm |
860*705*755 (Main instrument); 545*445*1385 (Accessories) |
Gross Weight(kg) |
105 (Main instrument); 100 (Accessories) |
Standard Accessories |
Software; Inkjet printer; Oil free Air compressor; Acetylene reducing valve; Cu Hollow cathode lamp; Air filter |
Optional Accessories |
Graphite Furnace 4510GF; Hollow cathode lamp(Ag, Au, Ca, Cd, Cr, Fe, Hg, K, Au, Mg, Mn, Na, Ni, Pb, Zn, Sb, etc), Graphite tubes, Recirculating cooling water system, Hydride generator, Autosampler |
Flame System:
Acetylene Air Burner |
100mm |
Ignition Dynamic Baseline Drift |
≤0.006A/30min |
Characteristic Concentration |
≤0.025μg/ml/1%(Cu) |
Related Standard Deviation of the Accuracy |
≤0.5%(Cu, absorbance>0.8A) (detection limit Cu≤0.008μg/ml) |
Safety System |
Can automatically cut off the gas when the pressure is not enough, the power is off, flameout and unconformity of the burner. |
Graphite Furnace(Optional):
Max. Temperature |
3000°C |
Max Heating Speed |
≥2000°C/S |
Characteristic Quantity |
Cd≤0.5*10T2g Cu≤0.5*1011g |
Accuracy |
Cu≤3% Cd≤3% |
Safety System |
Over current protection Low air pressure alarm/protection; Low cooling water flow alarm/protection |
Power Supply |
220V, 50Hz |
Consumption |
7000W |
Packing Size(W*D*H) mm |
740*640*700 |
Gross Weight(kg) |
90 |