• Biobase Table Top Process Gas Chromatograph for Sale
  • Biobase Table Top Process Gas Chromatograph for Sale
  • Biobase Table Top Process Gas Chromatograph for Sale
  • Biobase Table Top Process Gas Chromatograph for Sale
  • Biobase Table Top Process Gas Chromatograph for Sale
  • Biobase Table Top Process Gas Chromatograph for Sale

Biobase Table Top Process Gas Chromatograph for Sale

After-sales Service: Support
Warranty: 1 Year
Appliance: Medical Research
Ray Type: Gamma Ray Spectrometer
Gaspath System: Single or Double
Detector: FID
Customization:
Trading Company

360° Virtual Tour

Diamond Member Since 2022

Suppliers with verified business licenses

Shandong, China
Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Multi-language Pioneer
5 languages freely used by foreign trade staff. include: English, French, Russian, Arabic, Spanish
Experienced Team
The supplier has 10 foreign trading staff(s) and 7 staff(s) with over 6 years of overseas trading experience
to see all verified strength labels (13)
  • Overview
  • Product Parameters
  • Company Profile
  • After Sales Service
  • Customer Feedback
Overview

Basic Info.

Model NO.
BK-GC900
Energy Resolution
/
Certification
CE
Spectrometer Detector
/
Stationary Phase
Gas
Mobile Phase
Gas
Chromatography Type
Gas Chromatography
Chromatographic Column Type
Capilary Column
Chromatographic Column Length
/
Chromatographic Column Diameter
/
Temp. Range
Rt+5~450c
Temp. Program
20-Phase
Time Range
0-655min
Max Temp. Heating Rate
45c/Min
Net Weight
42kg
Package Size(W*D*H)
750*710*720mm
External Size(L*W*H)
530*502*508mm
Transport Package
Wooden
Specification
Gross weight: 60kg
Trademark
BIOBASE
Origin
China

Product Description

                           BIOBASE table top process gas chromatograph for sale

Product Parameters

Biobase Table Top Process Gas Chromatograph for Sale
Technical Parameters:

Model

BK-GC900

Oven

Temp. Range

RT+5~450ºC

Temp. Accuracy

≤±0.1ºC

Temp. Program

20-phase

Max. Temp. Heating Rate

40ºC/min

Time Range

0-655min

Internal Size

250*270*170mm

Detector

Hydrogen Flame Ionization Detector (FID)

Detection limit:≤5×10-12g/s

(100ng/ul n-hexadecane-isooctane solution)

Temperature 450ºC

Compatible with packed and capillary columns

Baseline drift:≤2x10-13A/30min

Baseline noise: 3×10-14A

Linear range:≥107

Thermal Conductivity Detector (TCD)

Sensitivity: >5000mv.ml/mg

(50mg/ml toluene-benzene solution)

Temperature 400ºC

Baseline drift:≤0.1mV/30min

Baseline noise: 0.03mV

Linear range:≥105(±10%)

Flame Photometric Detector (FPD)

Detection limit:≤5×10-12g/s(S of 10ng/ul methyl parathion-ethanol solution)

Detection limit:≤4×10-12g/s(P of 10ng/ul methyl parathion-ethanol solution)

Linear range (S): ≥103 

Linear range (P): ≥10

Temperature 350ºC

Injection Method

Various injection methods are available:

1) Packed column injection;

2) Packed column gasification injection;

3) Capillary split/splitless injection: back pressure valve control technology, linear split;

4) Six-way valve gas injection;

5) On-line injection: continuous injection for 24 hours without supervision

Power Supply

AC220V±10%, 50/60Hz

Standard Accessory

FID detector, Chromatography workstation software, Capillary sampler  

Optional Accessory

Sample injection system, TCD, FPD detector, Chromatographic column, Nickel catalytic converter

External Size(L*W*H)

530*502*508mm

Net Weight

42kg

Package Size (W*D*H)

750*710*720mm

Gross Weight

60kg


Features:

* Ethernet communication interface is adopted, so that the instrument can realize long-distance data transmission through the internal LAN of the enterprise, which is convenient for the management of analysis data

* The unique design of the injection port solves the injection discrimination, and the dual-column compensation function not only solves the baseline drift caused by temperature programming, but also reduces the influence of background noise, which can lead to lower detection limits.

* Unique vaporization chamber design, smaller dead volume; replacement of accessories such as injection pad, liner, polarizer, collector, nozzle can be done with one hand; packed column, capillary injector, TCD, FID detector and other main bodies The replacement only requires a wrench to be completely disassembled, and the maintenance is very convenient.

* The intelligent rear door system has stepless variable inlet and outlet air volume, which shortens the stable balance time of the system after programmed heating/cooling

* The inlet can be installed up to 4 types (packed column, capillary column split/splitless injection system can be used), multiple detectors with the same or different detectors are installed, automatic/manual gas injection device can be selected, top Empty sampler, thermal desorption sampler, pyrolysis furnace sampler, methane reformer, etc.

* The instrument is equipped with a 4.3-inch color LCD touch screen and keyboard input for user operation.

* Adopt the dual-stable gas path design of primary pressure stabilizer valve and stabilizer valve/pressure stabilizer valve

* With seven temperature control devices, the temperature control accuracy is lower than ±0.1ºC

* With double over-temperature protection and power-off protection function

* With linkage trigger signal acquisition system

* With fault self-check and alarm function

Company Profile

Biobase Table Top Process Gas Chromatograph for SaleBiobase Table Top Process Gas Chromatograph for SaleBiobase Table Top Process Gas Chromatograph for Sale

After Sales Service

Biobase Table Top Process Gas Chromatograph for Sale

Customer Feedback

Biobase Table Top Process Gas Chromatograph for Sale

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Product Groups

360° Virtual Tour

Diamond Member Since 2022

Suppliers with verified business licenses

Trading Company
Number of Employees
15
Year of Establishment
2017-02-09