After-sales Service: | Support |
---|---|
Warranty: | 1 Year |
Appliance: | Medical Research |
Ray Type: | Gamma Ray Spectrometer |
Gaspath System: | Single or Double |
Detector: | FID |
Customization: |
---|
Suppliers with verified business licenses
Technical Parameters:
Model |
BK-GC900 |
|
Oven |
Temp. Range |
RT+5~450ºC |
Temp. Accuracy |
≤±0.1ºC |
|
Temp. Program |
20-phase |
|
Max. Temp. Heating Rate |
40ºC/min |
|
Time Range |
0-655min |
|
Internal Size |
250*270*170mm |
|
Detector |
Hydrogen Flame Ionization Detector (FID) |
Detection limit:≤5×10-12g/s (100ng/ul n-hexadecane-isooctane solution) |
Temperature 450ºC |
||
Compatible with packed and capillary columns |
||
Baseline drift:≤2x10-13A/30min |
||
Baseline noise: 3×10-14A |
||
Linear range:≥107 |
||
Thermal Conductivity Detector (TCD) |
Sensitivity: >5000mv.ml/mg (50mg/ml toluene-benzene solution) |
|
Temperature 400ºC |
||
Baseline drift:≤0.1mV/30min |
||
Baseline noise: 0.03mV |
||
Linear range:≥105(±10%) |
||
Flame Photometric Detector (FPD) |
Detection limit:≤5×10-12g/s(S of 10ng/ul methyl parathion-ethanol solution) Detection limit:≤4×10-12g/s(P of 10ng/ul methyl parathion-ethanol solution) |
|
Linear range (S): ≥103 Linear range (P): ≥104 |
||
Temperature 350ºC |
||
Injection Method |
Various injection methods are available: 1) Packed column injection; 2) Packed column gasification injection; 3) Capillary split/splitless injection: back pressure valve control technology, linear split; 4) Six-way valve gas injection; 5) On-line injection: continuous injection for 24 hours without supervision |
|
Power Supply |
AC220V±10%, 50/60Hz |
|
Standard Accessory |
FID detector, Chromatography workstation software, Capillary sampler |
|
Optional Accessory |
Sample injection system, TCD, FPD detector, Chromatographic column, Nickel catalytic converter |
|
External Size(L*W*H) |
530*502*508mm |
|
Net Weight |
42kg |
|
Package Size (W*D*H) |
750*710*720mm |
|
Gross Weight |
60kg |
Features:
* Ethernet communication interface is adopted, so that the instrument can realize long-distance data transmission through the internal LAN of the enterprise, which is convenient for the management of analysis data
* The unique design of the injection port solves the injection discrimination, and the dual-column compensation function not only solves the baseline drift caused by temperature programming, but also reduces the influence of background noise, which can lead to lower detection limits.
* Unique vaporization chamber design, smaller dead volume; replacement of accessories such as injection pad, liner, polarizer, collector, nozzle can be done with one hand; packed column, capillary injector, TCD, FID detector and other main bodies The replacement only requires a wrench to be completely disassembled, and the maintenance is very convenient.
* The intelligent rear door system has stepless variable inlet and outlet air volume, which shortens the stable balance time of the system after programmed heating/cooling
* The inlet can be installed up to 4 types (packed column, capillary column split/splitless injection system can be used), multiple detectors with the same or different detectors are installed, automatic/manual gas injection device can be selected, top Empty sampler, thermal desorption sampler, pyrolysis furnace sampler, methane reformer, etc.
* The instrument is equipped with a 4.3-inch color LCD touch screen and keyboard input for user operation.
* Adopt the dual-stable gas path design of primary pressure stabilizer valve and stabilizer valve/pressure stabilizer valve
* With seven temperature control devices, the temperature control accuracy is lower than ±0.1ºC
* With double over-temperature protection and power-off protection function
* With linkage trigger signal acquisition system
* With fault self-check and alarm function