Biobase G Total Organic Carbon Analyzer Real-Time Monitoring with Conductivity Detector Toc Analyzer for Lab

Product Details
Customization: Available
After-sales Service: Online Technical Support
Warranty: 1 Year
Trading Company

360° Virtual Tour

Diamond Member Since 2022

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Multi-language Pioneer
5 languages freely used by foreign trade staff. include: English, French, Russian, Arabic, Spanish
Experienced Team
The supplier has 10 foreign trading staff(s) and 7 staff(s) with over 6 years of overseas trading experience
to see all verified strength labels (13)
  • Biobase G Total Organic Carbon Analyzer Real-Time Monitoring with Conductivity Detector Toc Analyzer for Lab
  • Biobase G Total Organic Carbon Analyzer Real-Time Monitoring with Conductivity Detector Toc Analyzer for Lab
  • Biobase G Total Organic Carbon Analyzer Real-Time Monitoring with Conductivity Detector Toc Analyzer for Lab
  • Biobase G Total Organic Carbon Analyzer Real-Time Monitoring with Conductivity Detector Toc Analyzer for Lab
  • Biobase G Total Organic Carbon Analyzer Real-Time Monitoring with Conductivity Detector Toc Analyzer for Lab
  • Biobase G Total Organic Carbon Analyzer Real-Time Monitoring with Conductivity Detector Toc Analyzer for Lab
Find Similar Products
  • Overview
  • Product Description
  • You May Also Like
  • Company Introduction
  • Why Choose Us?
  • Factory and Exhibition
  • FAQ
  • Contact Gerald
Overview

Basic Info.

Model NO.
BK-TOC1700
Analysis
Photoelectric Colorimetry
Display
Digital
Application
Ceramics and Glass
Frequency
50±1HZ
Performance
Automation
Function
Storage, Cleared
Weight
0-100Kg
Power Source
AC 220V, 50/60Hz (Standard); AC 110V, 50Hz (Option
Customized
Customized
Product Name
Total Organic Carbon Analyzer
Work Model
Online and Offline
Detection Range
0.001~1.5mg/L
Detection Limit
1ppb
Max Tolerance
5%
Analysis Time
3 Min
Response Time
Within 10 Min
Sample Temperature
1~95
Sample Flow Speed
3ml/Min
Repeatability Tolerance
3%
Drifting
5%
Transport Package
Wooden/Carton Packaging
Specification
External Size (W*D*H) 440*220*405mm
Trademark
BIOBASE
Origin
China
HS Code
1
Production Capacity
10000pieces/Year

Product Description

Total Organic Carbon Analyzer

Product Description

Biobase G Total Organic Carbon Analyzer Real-Time Monitoring with Conductivity Detector Toc Analyzer for Lab

Features:

•Equipped with conductivity detector to quantify TOC concentration.
•BK-TOC1700 is able to work under on-line mode to realize real-time monitoring
•Ideal choice to measure and monitor microelectronics water, purified water, water for injection, etc.
• Automatic sample introduction with one-button setting, no sample contamination, no harm on operator and environment
• UV oxidation by UV lamp, no need to add acid, gas or catalytic, greatly reduces the experiment and maintenance cost
• 7 inches touch screen with smart UI, easy to operate and read test data
• In compliance with FDA-21 CFR Part11 requirements and USP, EP, JP and CHP
• Auto sampler is optional according to different experiment requirements
• Online and offline mode can be easily switched. (BK-TOC1700)
• 8GB large storage capacity, no restriction of data and time
• Quick test, each analysis takes less than 3 minutes
• All historical records can be traced by searching test date
• Data can be retrieved and saved to USB directly
• Equipped with Bluetooth printer for quick and easy data printing
• Modular design for quick installation and easy maintenance
Model
BK-TOC1500
BK-TOC1700
Work Model
Offline
Online and offline
Detection Range
0.001~1.5mg/l
Detection Limit
1ppb
Max Tolerance
±5%
Analysis Time
3 min
Response Time
Within 10 min
Sample Temperature
1~95°C
Sample Flow Speed
3ml/min
Repeatability Tolerance
≤3%
Drifting
±5%
Environment Temperature
10-40ºC with temperature change ±5ºC/d
Relative Humidity
≤85%
Power Supply
AC 220V, 50/60Hz (Standard); AC 110V, 50Hz (Optional)
Consumption
100W
External Size(L*W*H)
440*220*300mm
440*220*405mm
Net Weight
11kg
12.25kg
Package Size(L*W*H)
610*470*405mm
640*490*440 mm
Gross Weight
16kg
18kg

You May Also Like

Biobase G Total Organic Carbon Analyzer Real-Time Monitoring with Conductivity Detector Toc Analyzer for Lab
Total Organic Carbon Analyzer
BK-TOC3000
• Equipped with signal management system to realize accurate online setting, real-time monitoring, self-testing and flow speed controlling, also ensures perfect device performance and experiment safety
• Low current system design highly ensures the safety of operators
• Temperature can be set according to different samples which ensures complete sample digestion
• The power of cooling module can be set according to sampling volume which improves drying performance, also prohibits wet gas damaging the NDIR detector.
• Automatic leakage checking system not only avoids mis-operations also improves device performance and operation safety.
• Flow rate controlling system avoids the influence of flow rate fluctuation which ensures more accurate data
• TOC detector with 24 bits data solution extends monitoring range. Controlling system with 32bin processing technology greatly improves device performance
 
Model
BK-TOC2000
BK-TOC3000
Method
Dry method
Wet Chemical Oxidation By UV
Digestion Mode
High Temperature Combustion
/
Detector
NDIR
Parameters
TC, TIC, TOC, NPOC
Gas Requirement
Oxygen ≥ 99.995%
Nitrogen ≥99 995%
Measurement Range
0~30000mg/l (ppm)
0~10000mg/l (ppm)
Detection Limit
50µg/l (ppb)
5µg/l (ppb)
Operation Mode
PC software Controlled
Application
Liquid Sample
Repeatability
3%
Maximum Salinity
85g/l
Power Supply
AC 220V, 50/60Hz (Standard); AC 110V, 50Hz (Optional)
Consumption
200W
External Size(L*W*H)
460*430*450mm
460*360*450mm
Net Weight
28kg
25kg
Package Size(L*W*H)
820*570*680mm
660*610*680 mm
Gross Weight
52kg
45kg
Biobase G Total Organic Carbon Analyzer Real-Time Monitoring with Conductivity Detector Toc Analyzer for Lab
Total Organic Carbon Analyzer
BK-TOC5000RN
• Equipped with signal management system to realize accurate online setting, real-time monitoring, self-testing and flow speed
controlling, also ensures perfect device performance and experiment safety
• Low current system design highly ensures the safety of operators
• Temperature can be set according to different samples which ensures complete sample digestion
• The power of cooling module can be set according to sampling volume which improves drying performance, also prohibits wet gas
damaging the NDIR detector.
• Automatic leakage checking system not only avoids mis-operations also improves device performance and operation safety.
• Flow rate controlling system avoids the influence of flow rate fluctuation which ensures more accurate data
• TOC detector with 24 bits data solution extends monitoring range. Controlling system with 32bin processing technology greatly
improves device performance
Model
BK-TOC5000RN
BK-TOC5000RD
Measurement Method
High temperature catalytic combustion
Detector
NDIR
Analysis Parameter
TC, TIC, TOC, NPOC
Control Mode
PC software controlled
Gas Requirement
Oxygen, purity ≥99.995%
Sample Type
Liquid sample(AS-W20 is optional.)
Solid sample( AS-S200 is needed.)
Measurement Range
0~1000mg/L, can extend to 0~100,000mg/L(Manually dilution)
0~1000mg/l, can extend to 0~100,000mg/L(Automatically dilution)
Limit of Detection
TC: 50μg/L
IC: 20μg/L
Measuring Time
TC: around 4min
IC: around 3min
Max. Permissible Error
TOC: ±5%
IC: ±4%
Repeatability
≤3%
Injection Volume
TC: 100~500μl
IC: 100~2000μl
Optional Accessories
Autosampler for liquid sample or solid sample
Enhanced Halogen Removal Device
Enhanced Halogen Removal Device-Metal Wire Mesh
Power Supply
AC220V±10%, 50/60Hz(Standard); 110V±10%, 50/60Hz(Optional)
Consumption
700W
Package Size(W*D*H)
Main Machine: 780*710*610mm
Accessories: 710*230*600mm
Gross Weight
Main Machine: 59kg
Accessories: 7kg
Main Machine: 63kg
Accessories: 8kg

Company Introduction


Biobase G Total Organic Carbon Analyzer Real-Time Monitoring with Conductivity Detector Toc Analyzer for Lab

Why Choose Us?


Biobase G Total Organic Carbon Analyzer Real-Time Monitoring with Conductivity Detector Toc Analyzer for LabBiobase G Total Organic Carbon Analyzer Real-Time Monitoring with Conductivity Detector Toc Analyzer for Lab

Factory and Exhibition

Biobase G Total Organic Carbon Analyzer Real-Time Monitoring with Conductivity Detector Toc Analyzer for Lab
Biobase G Total Organic Carbon Analyzer Real-Time Monitoring with Conductivity Detector Toc Analyzer for Lab

Biobase G Total Organic Carbon Analyzer Real-Time Monitoring with Conductivity Detector Toc Analyzer for Lab

 

FAQ

1.Q:Why choose BIOBASE?
A: We are the leading manufactuer in lab furniture and lab equipment, OEM & ODM service are offered.And we have our own overseas technician and installation team.

2.Q:Are you trading company or manufacturer?
A:We are professional and leading manufacturer in China. OEM & ODM sservice are accepted.

3.Q:How about the sample of Biobase product?
A:Yes,we could offer 1 unit sample machine,and make a PI for you including machine cost and shipping charge.

4.Q:How long is your delivery time?
A:It depends on quantity. Generally it is 7-10 working days if the goods are in stock. We try best to deliver as soon as possible.

5.Q:How about BIOBASE validity of quotation ?
A:Usually 30 days as the shipping freight and exchange rate can be fluctuant.

6.Q:How about Biobase payment term?
A:T/T,L/C,Paypal,Western union,moneygram are all acceptable for us.

7.Q:How about your quality warranty?
A: We have 1 year's quality warranty.

8.Q:What is the shipping port?
A:FOB to Qingdao Port,China(also can ship according to customers' request)

9.Q:How about the package?
A:Bubble film+Cotton +Standard export wooden case.

10.Q:How to inspect the goods?
A:Products will be checked by our QC staff first,then our project manager.Client can come and check by themselves or third party check is available.

Contact Gerald

Biobase G Total Organic Carbon Analyzer Real-Time Monitoring with Conductivity Detector Toc Analyzer for Lab

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier