Customization: | Available |
---|---|
Classification: | Biochemical Apparatus |
Type: | Biochemistry Analyzer |
Still deciding? Get samples of US$ 3655/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Viode
|
BK-410
|
|
Overall Performance |
Throughput
|
400Tests/hour,ISE(Optional)
|
Analysis Method
|
End-point,Fixed-time,Rate(Kinetic),Turbidimetry
|
|
System
|
Optional open or close system,continuous working for 24 hours
|
|
Sample & Reagent System |
Sample Positions
|
49sample positions
|
Reagent Position
|
56 reagent positions
|
|
Sample Volume
|
2-70μL
|
|
Reagent Volume
|
20-350μL
|
|
Probe
|
With anti-collision function,liquid level detection function
|
|
Probe Washing
|
Automatic washing interior and exterior
|
|
Reagent Cooling
|
2~12ºC for 24 hours
|
|
Reaction System |
Temperature Control
|
Water bath37±0.2ºC,real-time monitoring
|
Cuvettes
|
120 reusable cuvettes
|
|
Mixer Probe
|
Independent stirring,automatic frequency conversion
|
|
Washing
|
Automatic cuvettes washing
|
|
Optical System |
Light Source
|
Halogen lamp,water-cooling
|
Spectrophotometry
|
Post-spectral spectrophotometry
|
|
Wavelength
|
340~700nm
|
|
Absorbance
|
0~3.0Abs
|
|
Calibration &QC |
Calibration
|
Linear:K factor,1-point,2-point and multipoint linear Non-Linear:Spline,Polygon,Index,Ogarithm,Logit-4P,Logit-5F |
Quality Control
|
Real-time QC,Westgard multi rule,Cumulative Sum Check,Twin Plot(2D)
|
|
Data Management |
Software
|
Windows 7/8/10,32or 64bit
|
LIS System
|
Bi-direction,support HL7 protocol
|
|
Interface
|
LAN port access
|
|
Printer
|
External,multiple reporting mode available
|
|
Working Conditions |
Power Supply
|
AC220V±10%,50/60Hz(Standard),110V±10%60Hz(Optional),350VA
|
Temperature
|
15~30ºC(±2ºC)
|
|
Water Consumption
|
Deionized water<5L/h
|
|
Humidity
|
40~85%
|
|
Size &Weight |
External Size (W*D*H
|
) 873*585*500mm
|
Net Weight
|
80kg
|
|
Package Size (W*D*H)
|
1130*735*1040mm
|
|
Gross Weight
|
125kg
|
Model
|
BIOBASE-Claire
|
Reading Cuvette
|
Quartz cuvette
|
Photometric System |
Light source:6V,10W long life halogen lamp
|
|
Filters:340/405/450/510/546/578/630nm,2 more open filter positions
|
|
Wavelength accuracy:±2nm
|
Measuring System |
Measuring range:0~3.5000.D.
|
|
Photometric linearity:±2%from 0 to 2.500 O.D.
|
|
Photometric accuracy:±2%from 0 to 2.500 O.D.
|
|
Drift<0.005 O.D.
|
Display
|
Touch Screen
|
Printer
|
Built-in thermal printer
|
Interface
|
RS-232,USB
|
Power Supply
|
AC110/220V±10%,60/50Hz
|
External Size(W*D*H)
|
400*380*190mm
|
Package Size(W*D*H)
|
500*530*350mm
|
Gross Weighi
|
11kg
|
Model
|
BK-EL10C
|
|
Measurement Channel
|
Vertical 8 optical channels;
|
|
Wavelength Range
|
400~800 nm
|
|
Filter
|
Standard 4 wavelengths of 405,450,492,630nm;
can be installed up to 10 filters (optional) |
|
Reading Range
|
0.000~4.000 Abs
|
|
Linear Range
|
0.000-3.000 Abs
|
|
Repeatability
|
CV<1.0%
|
|
Stability
|
<±0.003Abs
|
|
Vibration Plate Function
|
3 kinds of vibration plate function,adjustable 0~255 seconds
|
|
Display
|
10.1-inch Large Touch Screen
|
|
Power Supply
|
AC110/220V, 60/50HZ
|
|
Net Weight
|
1 11kg
|
|
Gross Weight
|
13kg
|
|
Instrument Size (W*D*H)
|
450mm*320mm*300mm
|
|