BIOBASE 50L Hand wheel Autoclave with Dry function for laboratory sterilization BKQ-B50II
Features:
1. The hand wheel slides to open the door, which is fast and labor-saving.
2. Casters facilitate the movement of the equipment.
3. It has a fast maintenance window, and the electrical part does not need to remove the cover for maintenance.
4. Steam generation method: heating inside the main body, no external steam source is required.
5. Self-expanding silicone sealing ring has good sealing effect and long service life. It is molded with transparent medical silicone.
6. Real-time detection and display of the temperature in the sterilization chamber, with a display accuracy of 0.1ºC.
7. The LED digital tube displays temperature, time, alarm code and the indicator light shows the current operating status.
8. Using gravity displacement and positive pressure pulsating exhaust method to discharge the cold air in the load and sterilization room.
9. Optional printer to record the temperature during sterilization.
10. Drying function and inner water tank(except for BKQ-B150/200(II))
Application:
It is widely used in laboratories, inspection departments, food processing enterprises, etc. for sterilization of equipment and medical waste. It uses gravity displacement to discharge the cold air in the sterilization chamber to ensure the sterilization effect.
Model
|
BKQ-B50II
|
BKQ-B75II
|
BKQ-B100II
|
BKQ-B120BII
|
BKQ-B150(II)
|
BKQ-B200(II)
|
Capacity
|
50L
|
75L
|
100L
|
120L
|
150L
|
200L
|
Chamber Size(mm)
|
φ386*514
|
φ386*694
|
φ386*874
|
φ386*1054
|
φ500*760
|
φ500*1000
|
Chamber Material
|
S30408
|
|||||
Designed Pressure
|
0.28Mpa
|
0.217Mpa
|
||||
Designed Temp
|
134ºC
|
138ºC
|
||||
Working Pressure
|
0.23MPa
|
0.217MPa
|
||||
Working temp.
|
105~136ºC
|
50~134ºC
|
||||
Temp. Displayaccuracy
|
0.1ºC
|
|||||
Timing range
|
0~999min
|
0~99h
|
||||
Dynamic Pulse
Exhaust Times |
0~9 times
|
/
|
||||
Dynamic Pulse
Exhaust Temp. |
105~136ºC
|
|||||
Dissolution Temp.
Range |
60~100ºC(programmable)
|
|||||
Temp. Holding Range
|
45~60ºC(programmable)
|
50-100°C (programmable)
|
||||
Consumption
|
4.4KW
|
4.7KW
|
5.2KW
|
5.2KW
|
6KW
|
|
Power Supply
|
AC110/220V±10%, 50/60Hz
|
380V, 50Hz/200V, 50/60Hz
|
||||
SS Basket
|
1 pc
|
2pcs
|
2pcs
|
3pcs
|
3 pcs
|
4pcs
|
External Size (W*D*H)mm
|
640*550*970
|
640*550*1070
|
640*550*1270
|
640*550*1370
|
650*650*1400
|
650*650*1700
|
Packing Size (W*D*H)mm
|
750*745*1100
|
750*745*1240
|
750*745*1450
|
750*745*1540
|
800*760*1530
|
800*760*1720
|
Gross Weight(kg)
|
102
|
112
|
125
|
140
|
213
|
238
|
Air protection | Cold Chain Product | General Lab Equipment | Analytical Instrument |
Biosafety Cabinet | Medical Refrigerator | Autoclave | Chemistry Analyzer |
Laminar Flow Cabinet | Blood Bank Refrigerator | Incubator | ELISA Reader & Washer |
Fume Hood | -25 Freezer | Drying Oven | Hematology Analyzer |
Clean Room | -40 Freezer | Centrifuge | Electrolytic Analyzer |
PCR Cabinet | -60 Freezer | Spectrophotometer | Urine Analyzer |
ect. | -86 Freezer etc. | Shaker etc. | ect. |
Package
Delivery
Factory
Showroom
Exhibition