Model
|
BK-GC7820
|
|
|
Oven
|
Temp. Range
|
RT~450ºC
|
|
Temp. Accuracy
|
≤±0.1ºC
|
|
|
Temp. Program
|
16-phase
|
|
|
Max. Temp. Heating Rate
|
40ºC/min
|
|
|
Detector
|
Hydrogen Flame Ionization Detector (FID)
|
Detection limit:≤3×10-12g/s (Sample: n-hexadecane)
|
|
Baseline drift:≤1x10-13A/30min
|
||
|
Linear range:≥107
|
||
|
Thermal Conductivity Detector (TCD) (Optional)
|
Sensitivity: >10000mv.ml/mg (Sample: n-hexadecane)
|
|
|
Linear range:≥105
|
||
|
Electron Capture Detector (ECD) (Optional)
|
Detection limit:≤1×10-14g/ml
(Sample: n-hexadecaneδ-666) |
|
|
Linear range:≥103
|
||
|
Flame Photometric Detector (FPD) (Optional)
|
Detection limit:≤2×10-11g/s (S of thiophene)
Detection limit:≤1×10-12g/s (P of methyl parathion) |
|
|
Linear range (S):≥102
Linear range (P):≥103 |
||
|
Nitrogen and Phosphorus Detector (NPD) (Optional)
|
Detection limit:≤1×10-12g/s (Azobenzene)
Detection limit:≤1×10-12g/s (Marla sulphur phosphorous) |
|
|
Linear range:≥103
|
||
|
Power Supply
|
AC110/220V±10%, 50/60Hz
|
|
|
Standard Accessory
|
FID detector, Chromatography workstation software
|
|
|
Optional Accessory
|
Sample injection system, TCD, ECD, FPD and NPD detector, Chromatographic column.
|
|
|
Package Size (W*D*H)
|
800*570*650mm
|
|
|
Gross Weight
|
75kg
|
|
|
Model
|
BK-GC112A
|
|
|
Oven
|
Capacity
|
22L
|
|
Temp. Range
|
RT+5°C~400°C
|
|
|
Temp. Accuracy
|
±0.1 °C
|
|
|
Temp. Program
|
9 step
|
|
|
Program Total Time
|
9999.9 min
|
|
|
Max Temp. Heating Rate
|
60°C/min
|
|
|
Sample Injector
|
Temp. Range
|
RT+7°C~420°C
|
|
Column or split injector can be installed
|
||
|
Carrier gas flow control type: Constant pressure mode
|
||
|
Max. Quantity
|
3pcs
|
|
|
Pre Column Pressure Range
|
0-400kpa
|
|
|
Pre Column Pressure Accuracy
|
0.1 kpa
|
|
|
Flow Setting Range
|
H2: 0-200ml/min
|
|
|
N2: 0-150ml/min
|
||
|
Detector
|
Temp. Range
|
RT+7°C~420°C
|
|
Hydrogen Flame Ionization Detector (FID)
|
Logarithmic amplifier
|
|
|
High voltage switch control
|
||
|
Baseline signal display
|
||
|
Detection limit: ^3*1012g/s (Sample: n-hexadecane)
|
||
|
Baseline noise: <5*1014A
|
||
|
Baseline draft: 6*1 O ^A
|
||
|
Dynamic range: 107
|
||
|
RSD:£3%
|
||
|
Thermal Conductivity Detector (TCD)(Optional)
|
Sensitivity: 8000mv.ml/mg(Sample: n-hexadecane)
|
|
|
Baseline noise: <0.05mV
|
||
|
Baseline draft: <0.15mV/30min
|
||
|
Dynamic range: 105
|
||
|
Power Supply
|
AC220V±10%, 50Hz
|
|
|
Standard Accessory
|
FID detector, Capillary injection system, Chromatography workstation software,RS232 port, LAN port
|
|
|
Optional Accessory
|
TCD detector, Chromatographic column, Gas purifier
|
|
|
Package Size(W*D*H)
|
735*725*835mm
|
|
|
Gross Weight
|
80kg
|
|
|
Model
|
BK-GC7820
|
|
|
Oven
|
Temp. Range
|
RT~450ºC
|
|
Temp. Accuracy
|
≤±0.1ºC
|
|
|
Temp. Program
|
16-phase
|
|
|
Max. Temp. Heating Rate
|
40ºC/min
|
|
|
Detector
|
Hydrogen Flame Ionization Detector (FID)
|
Detection limit:≤3×10-12g/s
(Sample: n-hexadecane) |
|
Baseline drift:≤1x10-13A/30min
|
||
|
Linear range:≥107
|
||
|
Thermal Conductivity Detector (TCD) (Optional)
|
Sensitivity: >10000mv.ml/mg
(Sample: n-hexadecane) |
|
|
Linear range:≥105
|
||
|
Electron Capture Detector (ECD) (Optional)
|
Detection limit:≤1×10-14g/ml
(Sample: n-hexadecaneδ-666) |
|
|
Linear range:≥103
|
||
|
Flame Photometric Detector (FPD) (Optional)
|
Detection limit:≤2×10-11g/s (S of thiophene)
Detection limit:≤1×10-12g/s (P of methyl parathion) |
|
|
Linear range (S):≥102
Linear range (P):≥103 |
||
|
Nitrogen and Phosphorus Detector (NPD) (Optional)
|
Detection limit:≤1×10-12g/s (Azobenzene)
Detection limit:≤1×10-12g/s (Marla sulphur phosphorous) |
|
|
Linear range:≥103
|
||
|
Power Supply
|
AC110/220V±10%, 50/60Hz
|
|
|
Standard Accessory
|
FID detector, Chromatography workstation software
|
|
|
Optional Accessory
|
Sample injection system, TCD, ECD, FPD and NPD detector, Chromatographic column.
|
|
|
Package Size (W*D*H)
|
800*570*650mm
|
|
|
Gross Weight
|
75kg
|
|



1.Q:Why choose BIOBASE?
A: We are the leading manufactuer in lab furniture and lab equipment, OEM & ODM service are offered.And we have our own overseas technician and installation team.
2.Q:Are you trading company or manufacturer?
A:We are professional and leading manufacturer in China. OEM & ODM sservice are accepted.
3.Q:How about the sample of Biobase product?
A:Yes,we could offer 1 unit sample machine,and make a PI for you including machine cost and shipping charge.
4.Q:How long is your delivery time?
A:It depends on quantity. Generally it is 7-10 working days if the goods are in stock. We try best to deliver as soon as possible.
5.Q:How about BIOBASE validity of quotation ?
A:Usually 30 days as the shipping freight and exchange rate can be fluctuant.
6.Q:How about Biobase payment term?
A:T/T,L/C,Paypal,Western union,moneygram are all acceptable for us.
7.Q:How about your quality warranty?
A: We have 1 year's quality warranty.
8.Q:What is the shipping port?
A:FOB to Qingdao Port,China(also can ship according to customers' request)
9.Q:How about the package?
A:Bubble film+Cotton +Standard export wooden case.
10.Q:How to inspect the goods?