Biobase Atomic Absorption Spectrophotometer Double Beam 190-900nmaas Machine Bk-AA320n

Product Details
Customization: Available
After-sales Service: Online Services
Application: Laboratory Apparatus
Still deciding? Get samples of US$ 5930/unit
Request Sample
Trading Company

360° Virtual Tour

Diamond Member Since 2022

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Multi-language Pioneer
5 languages freely used by foreign trade staff. include: English, French, Russian, Arabic, Spanish
Experienced Team
The supplier has 10 foreign trading staff(s) and 7 staff(s) with over 6 years of overseas trading experience
to see all verified strength labels (13)
  • Biobase Atomic Absorption Spectrophotometer Double Beam 190-900nmaas Machine Bk-AA320n
  • Biobase Atomic Absorption Spectrophotometer Double Beam 190-900nmaas Machine Bk-AA320n
  • Biobase Atomic Absorption Spectrophotometer Double Beam 190-900nmaas Machine Bk-AA320n
  • Biobase Atomic Absorption Spectrophotometer Double Beam 190-900nmaas Machine Bk-AA320n
  • Biobase Atomic Absorption Spectrophotometer Double Beam 190-900nmaas Machine Bk-AA320n
  • Biobase Atomic Absorption Spectrophotometer Double Beam 190-900nmaas Machine Bk-AA320n
Find Similar Products
  • Overview
  • Company Profile
  • One-Stop Shopping
  • After-Sales Service & Feedback
  • Contact Cherry
Overview

Basic Info.

Model NO.
Bk-AA320n
Warranty
1 Year
Detection Method
Spectrophotometer
Advantage
High Sensitive
Principle
Classic Spectrometer
Wavelengths
UV Spectrometer
Dispersive Element
/
Light Number
/
Certification
CE
Customized
Customized
Model
Bk-AA320n
Wavelength Range
190~900nm
Wavelength Accuracy
0.5nm
Wavelength Repeatability
0.3nm (Single Direction)
Spectral Bandwidth
0.2nm, 0.4nm, 0.7nm, 1.4nm, 2.4nm, 5.0nm
Resolution
40%
Base Line Stability
0.004ABS/30min
Characteristic Concentration
0.04ug/Ml/1% (Cu)
Detection Limit
0.008ug/Ml (Cu)
Background Calibration
30 Times
Power Supply
220V, 50/60Hz
Gross Weight(Kg)
150kg (Main Instrument) 50kg ( Accessories )
Transport Package
Wooden Carton
Specification
150Kg
Trademark
BIOBASE
Origin
China
Production Capacity
5000

Product Description

BIOBASE Atomic Absorption Spectrophotometer Double beam 190-900nmAAS machine BK-AA320N  

 
Biobase Atomic Absorption Spectrophotometer Double Beam 190-900nmaas Machine Bk-AA320n
Biobase Atomic Absorption Spectrophotometer Double Beam 190-900nmaas Machine Bk-AA320n
Biobase Atomic Absorption Spectrophotometer Double Beam 190-900nmaas Machine Bk-AA320n
Features:
1. Build-in computer data processing and LCD display.
2. Stability: Double-beam system can automatically compensate the light source drift and wavelength drift caused by the variation of temperature and electronic circuit drift.
3. Quickly: The cathode lamp needs not be pre-heated for long time and sample can be analyzed immediately.
4. High precision of measurement: Gas path system is equipped with precision pressure stabilizing and current stabilizing devices to reach stable flame and low noise. Specially designed fine light beam passes through the flame to ensure a high precision analytical test and low characteristic concentration.
5. High energy optical path.
6. Long-life and anti-corrosive atomization system.
7. Multi-functional analysis mode: ?flame absorption?flame emission? graphite furnace atomic absorption hydride generation.
8. Safe and reliable gas path system: Special devices of quick gas conversion and safety protection can be used to analyze air-acetylene flame as well as nitrous oxide-acetylene flame and extend the analytic elements to reach more than 60.

Technical Parameters:

Model

BK-AA320N

Wavelength Range

190~900nm

Wavelength Accuracy

≤±0.5nm

Wavelength Repeatability

≤ 0.3nm (single direction)

Spectral Bandwidth

0.2nm, 0.4nm, 0.7nm, 1.4nm, 2.4nm, 5.0nm

Grating

1800 lines/mm

Resolution

<40%

Base Line Stability

±0.004Abs/30min

Characteristic Concentration

≤ 0.04μg/ml/1% (Cu)

Detection Limit

≤0.008μg/ml (Cu)

Background Calibration

>30 times

Power Supply

220V, 50/60Hz

Packing Size(mm)

1250*795*765 (Main instrument)

545*445*1385 ( Accessories )

Gross Weight(kg)

138Kg (Main instrument)

56Kg ( Accessories )

Standard Accessories

RS232 serial port

Oil-free air compressor

Glass Atomizer

Cu Hollow cathode lamp

Atomizer unit, Burner unit ,Dust cover

Water-separating gas filter

Titanium burner---10cm

Optional Accessories

Model GA3202 HGA graphite furnace system

Hydride generator

Graphite tubes

Recirculating cooling water system

Hollow cathode lamp(Ag, Au, Ca, Cd, Cr ,Fe, Hg ,K, AU, Mg,Mn, Na, Ni, Pb, Zn, Sb,etc)

Company Profile

Biobase is specialized in products of many areas including laboratory equipment, cleaning and disinfection equipment, laboratory safety protection product, cold chain product, medical equipment, general analytical equipment, measuring equipment, physical test equipment and some industry research equipment.Our company is committed to creating a one-stop scientific instrument procurement ecological chain.

Biobase has a strong international trading team. With excellent research team, strong quality control team, professional sales team and responsible after-sale service team, Biobase Meihua will provide you quality products and offer training service on the installation and maintenance of all of the products. Especially our engineers are experienced on hands-on design,  testing and trouble shooting.
Biobase Atomic Absorption Spectrophotometer Double Beam 190-900nmaas Machine Bk-AA320n

Exhibition Hall


Biobase Atomic Absorption Spectrophotometer Double Beam 190-900nmaas Machine Bk-AA320n

Factory

Biobase Atomic Absorption Spectrophotometer Double Beam 190-900nmaas Machine Bk-AA320n
Biobase Atomic Absorption Spectrophotometer Double Beam 190-900nmaas Machine Bk-AA320n

 

Exhibition

Biobase Atomic Absorption Spectrophotometer Double Beam 190-900nmaas Machine Bk-AA320n
Biobase Atomic Absorption Spectrophotometer Double Beam 190-900nmaas Machine Bk-AA320n

 

One-Stop Shopping

Biobase Atomic Absorption Spectrophotometer Double Beam 190-900nmaas Machine Bk-AA320n

Biobase Atomic Absorption Spectrophotometer Double Beam 190-900nmaas Machine Bk-AA320n
Biobase Atomic Absorption Spectrophotometer Double Beam 190-900nmaas Machine Bk-AA320n

 

Biobase Atomic Absorption Spectrophotometer Double Beam 190-900nmaas Machine Bk-AA320n
Biobase Atomic Absorption Spectrophotometer Double Beam 190-900nmaas Machine Bk-AA320n
Biobase Atomic Absorption Spectrophotometer Double Beam 190-900nmaas Machine Bk-AA320n

 

After-Sales Service & Feedback

Our service:

1. 100% product quality guarantee
2. Quick delivery time
3. Promptly reply you within 24hours
4. OEM service

 

Biobase Atomic Absorption Spectrophotometer Double Beam 190-900nmaas Machine Bk-AA320n
Biobase Atomic Absorption Spectrophotometer Double Beam 190-900nmaas Machine Bk-AA320n


Biobase Atomic Absorption Spectrophotometer Double Beam 190-900nmaas Machine Bk-AA320n

 
Biobase Atomic Absorption Spectrophotometer Double Beam 190-900nmaas Machine Bk-AA320n
Biobase Atomic Absorption Spectrophotometer Double Beam 190-900nmaas Machine Bk-AA320n

Packing and Delivery
Biobase Atomic Absorption Spectrophotometer Double Beam 190-900nmaas Machine Bk-AA320n

Contact Cherry


Biobase Atomic Absorption Spectrophotometer Double Beam 190-900nmaas Machine Bk-AA320n
 
 
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier