Customization: | Available |
---|---|
After-sales Service: | Online Technical Service Provider |
Warranty: | 1 Year |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Features:
* Completely controlled by PC, can flexibly select the flame and graphite furnace atomizer (optional).
* Integrated floated optical platform design improves the optical system shock resistance stable.
* Eight light stands can be changed automatically and preheat the eight lights meantime as well as optimize the working condition of the hollow cathode lamp.
* Position adjusting: the flame burner can be set on the best position automatically.
* Fully automated wavelength scanning and peak searching.
* Complete safety chains protection equipment: warning and automatic safety protection for the wrong burner connection, leakage of the gas, under voltage of air and the abnormal flameout.
* lamp and self-absorption background calibration.
* Measuring method: flame absorption method and emission method.
* Result printing: parameter, data result and diagram.
* Data processing: more than 500 data self-storage and cut-off storage, the analyzed result is stored in EXCEL format.
Model |
BK-AA4530F |
Wavelength Range |
190~900nm |
Spectral Bandwidth |
0.1, 0.2, 0.4, 1.0 and 2.0nm |
Wavelength Accuracy |
≤±0.15nm |
Wavelength Receptivity |
≤0.04nm |
Base Line Stability |
≤0.002A/30min (Cu) |
Characteristic Concentration |
0.02μg/ml/1% (Cu) |
Detection Limit |
0.004μg/ml (Cu) |
Measurement Repeatability |
≤0.5% |
Grating |
1800 lines/mm |
Inflamer |
All-metal titanium burner |
Atomizer |
Efficient glass atomizer |
Lamp stand |
8 |
D2 background Calibration |
When the background is 1 A, the background ability should be deducted not less than 50 times; self absorption background deduction method |
Power Supply |
220V, 50/60Hz |
Packing Size(mm) |
850*700*750(Main instrument) 950*620*1020(Accessories ) |
Gross Weight(kg) |
105Kg (Main instrument) 100Kg ( Accessories ) |
Standard Accessories |
PC workstation HP inkjet printer Oil free Air compressor Acetylene reducing valve Cu Hollow cathode lamp Air filter |
Optional Accessories |
Graphite Furnace 4510GF Hollow cathode lamp(Ag, Au, Ca, Cd, Cr ,Fe, Hg ,K, AU, Mg,Mn, Na, Ni, Pb, Zn, Sb,etc) |
FLAME SYSTEM
Acetylene Air Burner |
100mm |
Ignition Dynamic Baseline Drift |
≤0.006A/30min |
Characteristic Concentration |
≤0.025μg/ml/1%(Cu) |
Related Standard Deviation of the Accuracy |
≤0.5%(Cu, absorbance>0.8A) (detection limit Cu≤0.008μg/ml) |
Safety System |
Can automatically cut off the gas when the pressure is not enough, the power is off, flameout and unconformity of the burner. |
GRAPHITE FURNACE(Optional):
Max. Temperature |
3000ºC |
Max Heating Speed |
≥2000ºC/S |
Characteristic Quantity |
Cd≤0.5*10-12g Cu≤0.5*10-11g |
Accuracy |
Cu≤3% Cd≤3% |
Safety System |
Over current protection Low air pressure alarm / protection Low cooling water flow alarm/protection |
Power Supply |
220V, 50Hz/60Hz |
Consumption |
7000W |
Packing Size(mm) |
740*640*700 |
Gross Weight(kg) |
90 |