After-sales Service: Online Technical Support
Warranty: 1 Yeas
Appliance: The Analysis of Environmental Samples
Ray Type: /
Gaspath System: Three
Detector: FID
Customization:
Trading Company

360° Virtual Tour

Diamond Member Since 2022

Suppliers with verified business licenses

Shandong, China
Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Multi-language Pioneer
5 languages freely used by foreign trade staff. include: English, French, Russian, Arabic, Spanish
Experienced Team
The supplier has 10 foreign trading staff(s) and 7 staff(s) with over 6 years of overseas trading experience
to see all verified strength labels (13)
  • Overview
  • Product Description
  • Product Parameters
  • Company Profile
  • FAQ
  • You may also like
  • Contact us
Overview

Basic Info.

Model NO.
BK-GC901
Energy Resolution
/
Certification
/
Spectrometer Detector
/
Stationary Phase
Solid Adsorbent
Mobile Phase
Gas
Chromatography Type
Gas Chromatography
Chromatographic Column Type
Capilary Column
Chromatographic Column Length
/
Chromatographic Column Diameter
/
Product Name
Gas Chromatograph
Temp. Range
Rt+5~450c
Temp. Accuracy
0.01c
Temp. Program
16-Phase
Max. Temp. Heating Rate
40c/Min
Time Range
0-999.9min
Inlet
1~4
Transport Package
Wooden Boxes or Carton.
Specification
750*710*720
Trademark
BIOBASE
Origin
China
HS Code
9027201100
Production Capacity
10000pieces/Year

Product Description

Biobase Gc Gas Chromatography Fid Tcd Fpd Chromatography Gas Liquid Laboratory Column Gas Chromatography for Lab

Product Description


Application:

BK-GC901 gas chromatograph can realize full EPCelectronic flow control, realize full computer control of theinstrument, and can be equipped with a high-precisionliquid automatic sampler.

It can be widely used in manyfields such as petroleum, chemical industry, environmentalprotection, food safety, disease control, education andscientific research, and can analyze the macro, micro andtrace amounts of organic matter, inorganic matter and gas.


Biobase Gc Gas Chromatography Fid Tcd Fpd Chromatography Gas Liquid Laboratory Column Gas Chromatography for LabFeature:
 High-precision gas flow control system (EPC) 
* High-precision gas flow control, to ensure the accuracy of GC analysis, to ensure
the efficiency of daily analysis, EPC control accuracy 0.01psi. 
* It realizes the self-protection of gas circuit failure, automatic ignition, re-ignition, automatic opening of the gas circuit, and one-key start. 
* A variety of control combination modes of operation, automatic pressure and flow adjustment, control and display, can operate in gas-saving mode. 

Color widescreen, unique design of touch keys 
* 7-inch industrial color LCD screen design, more complete display information, more reasonable
interface operation.
 * Have two sets of operating systems in Chinese and English to meet different user needs. 
* Adopt resistive touch screen, feel good, durable, double operation of screen and software to achieve seamless connection. 

Leading structural design 
* Modular structure design, easy to upgrade, can be equipped with a variety of high-performance detectors such as FID, TCD,ECD, FPD and NPD, etc., to meet the analysis needs of complex samples. 
* Advanced sampler design, unique liner structure and special processing technology to ensure zero adsorption of samples. 
* Adapt to a variety of sample injection methods such as: headspace sampler, thermal desorption analyzer, liquid automatic sampler, easily competent for the analysis of various sample types. 
* Timed self-starting program can easily complete the laboratory online analysis of gas and liquid samples. Humanized software operating system
* Adopt advanced 10/100M self-adaptive Ethernet communication interface, built-in IP protocol stack,
easily form a local area network, realize long-distance transmission, remote control, and remote diagnosis. 
* Equipped with IBrainChrom workstation, which can support multiple chromatographs (253 sets) to work at the same time, realize data processing and reverse control. 

Data processing and countermeasures 
* Have complete audit trail, user rights management, electronic signature and other functions, so that data and documents meet GMP management requirements. 
* The built-in Modbus/TCP server of IBrainChrom workstation can easily connect the analysis results to DCS (distributed control system). 
* 3 independent connection threads that can be connected to local, laboratory supervisors and authorities, allowing them to monitor the operation of the instrument and analyze the data in real time.


 
Biobase Gc Gas Chromatography Fid Tcd Fpd Chromatography Gas Liquid Laboratory Column Gas Chromatography for Lab
Biobase Gc Gas Chromatography Fid Tcd Fpd Chromatography Gas Liquid Laboratory Column Gas Chromatography for Lab
Biobase Gc Gas Chromatography Fid Tcd Fpd Chromatography Gas Liquid Laboratory Column Gas Chromatography for Lab

Product Parameters

 
Model
BK-GC901
Oven
Temp. Range
RT+5~450ºC
Temp. Accuracy
≤±0.1ºC
Temp. Program
16-phase
Max. Temp. Heating Rate
40ºC/min
Time Range
0-999min
Internal Size
250*270*170mm
Detector
Hydrogen Flame Ionization Detector (FID)
Detection limit:≤5×10-12g/s
(100ng/(µl n-hexadecane-isooctane solution)
Temperature 450ºC
Compatible with packed and capillary columns
Baseline drift:≤2x10-13A/30min
Baseline noise: 3×10-14A
Linear range:≥107
Thermal Conductivity Detector (TCD)
Sensitivity: >5000mv.ml/mg
(50mg/ml toluene-benzene solution)
Temperature 400ºC
Baseline drift:≤0.1mV/30min
Baseline noise: 0.03mV
Linear range:≥105(±10%)
Flame Photometric Detector (FPD)
Detection limit:≤5×10-12g/s(S of 10ng/(µl methyl parathion-ethanol solution)
Detection limit:≤4×10-12g/s(P of 10ng/(µl methyl parathion-ethanol solution)
Linear range (S): ≥103
Linear range (P): ≥104
Temperature 350ºC
Power Supply
AC220V±10%, 50/60Hz
Standard Accessory
FID detector, Chromatography workstation software, Capillary sampler
Optional Accessory
Sample injection system, TCD, FPD detector, Chromatographic column
Package Size (W*D*H)
750*710*720mm
Gross Weight
70kg

 

 

Company Profile

Biobase Gc Gas Chromatography Fid Tcd Fpd Chromatography Gas Liquid Laboratory Column Gas Chromatography for LabBiobase Gc Gas Chromatography Fid Tcd Fpd Chromatography Gas Liquid Laboratory Column Gas Chromatography for Lab
Biobase Gc Gas Chromatography Fid Tcd Fpd Chromatography Gas Liquid Laboratory Column Gas Chromatography for Lab
Biobase Gc Gas Chromatography Fid Tcd Fpd Chromatography Gas Liquid Laboratory Column Gas Chromatography for LabBiobase Gc Gas Chromatography Fid Tcd Fpd Chromatography Gas Liquid Laboratory Column Gas Chromatography for LabBiobase Gc Gas Chromatography Fid Tcd Fpd Chromatography Gas Liquid Laboratory Column Gas Chromatography for Lab

Biobase Gc Gas Chromatography Fid Tcd Fpd Chromatography Gas Liquid Laboratory Column Gas Chromatography for Lab

FAQ

1. Are you a manufacture?
We are a professional manufacturer of laboratory analytical equipment, and a complete laboratory solution provider.

We provide you with a comprehensive solution to all your in-vitro medical equipment requirements. From the high-class complicated to highly sensitive ones, we have everything in place for our valuable clients.

2. How are your service?
Unparalleled services:
When it comes to providing the clients with unparalleled experience, we believe in delivering the same through unmatched customer service. From the moment you put your foot at our store to the after-sale, we provide you with the maximum assistance to ensure you enjoy the ultimate customer delights.

3. Do you support OEM or ODM?
We've successfully provided OEM/ODM service to a lot of customers.

4. Do you ship to our country?
We give the professional logistic solution to the Variety of goods as per the specialty of each (goods), whether it is
sensitive reagent kits or most urgent expected demo item, all can be shipped with great care.

5. What is your leading time?
Leading time various on different items, some analytical equipment is 10-15 days, because we ensure each equipment tested carefully before shipment.

6. Will I get after sale technical support?
Yes, Biobase has built a professional after-sale team who has rich experience with customers overseas, 24 hour online to answer your question.

7. What is your advantage?
Quality and service, those two are always our pursue.

You may also like

Biobase Gc Gas Chromatography Fid Tcd Fpd Chromatography Gas Liquid Laboratory Column Gas Chromatography for LabBiobase Gc Gas Chromatography Fid Tcd Fpd Chromatography Gas Liquid Laboratory Column Gas Chromatography for Lab

Contact us

Biobase Gc Gas Chromatography Fid Tcd Fpd Chromatography Gas Liquid Laboratory Column Gas Chromatography for Lab

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

360° Virtual Tour

Diamond Member Since 2022

Suppliers with verified business licenses

Trading Company
Number of Employees
15
Year of Establishment
2017-02-09