High Quality Automatic Chemiluminescence Immunoassay System Analyzer Bki1100

Biobase Biolin Co., Ltd.
  • Audited Supplier
  • 5 yrs

Contact Supplier

Product Highlights

  • High Throughput Performance: Delivers 80 tests per hour for efficient laboratory workflow.
  • Rapid First Result: Provides initial results in just 18 minutes for quick diagnosis.
  • Advanced Separation Technology: Uses magnetic particle enzymatic chemiluminescence for high sensitivity.
  • Large Sample Capacity: Disc design supports up to 60 sample positions per batch.
  • High Precision Detection: Ensures detection precision with CV less than or equal to 5%.
  • Comprehensive Test Menu: Covers Thyroid, Tumor, Hormone, and Infectious disease markers.
  • Flexible Customization: Offers full, minor, and flexible customization from samples or designs.

Product Images of High Quality Automatic Chemiluminescence Immunoassay System Analyzer Bki1100

High Quality Automatic Chemiluminescence Immunoassay System Analyzer Bki1100
High Quality Automatic Chemiluminescence Immunoassay System Analyzer Bki1100 pictures & photos
High Quality Automatic Chemiluminescence Immunoassay System Analyzer Bki1100
High Quality Automatic Chemiluminescence Immunoassay System Analyzer Bki1100 pictures & photos
High Quality Automatic Chemiluminescence Immunoassay System Analyzer Bki1100
High Quality Automatic Chemiluminescence Immunoassay System Analyzer Bki1100 pictures & photos
High Quality Automatic Chemiluminescence Immunoassay System Analyzer Bki1100
High Quality Automatic Chemiluminescence Immunoassay System Analyzer Bki1100 pictures & photos
High Quality Automatic Chemiluminescence Immunoassay System Analyzer Bki1100
High Quality Automatic Chemiluminescence Immunoassay System Analyzer Bki1100 pictures & photos
High Quality Automatic Chemiluminescence Immunoassay System Analyzer Bki1100
High Quality Automatic Chemiluminescence Immunoassay System Analyzer Bki1100 pictures & photos
High Quality Automatic Chemiluminescence Immunoassay System Analyzer Bki1100
  • High Quality Automatic Chemiluminescence Immunoassay System Analyzer Bki1100
  • High Quality Automatic Chemiluminescence Immunoassay System Analyzer Bki1100
    High Quality Automatic Chemiluminescence Immunoassay System Analyzer Bki1100
  • High Quality Automatic Chemiluminescence Immunoassay System Analyzer Bki1100
    High Quality Automatic Chemiluminescence Immunoassay System Analyzer Bki1100
  • High Quality Automatic Chemiluminescence Immunoassay System Analyzer Bki1100
    High Quality Automatic Chemiluminescence Immunoassay System Analyzer Bki1100
  • High Quality Automatic Chemiluminescence Immunoassay System Analyzer Bki1100
    High Quality Automatic Chemiluminescence Immunoassay System Analyzer Bki1100
  • High Quality Automatic Chemiluminescence Immunoassay System Analyzer Bki1100
    High Quality Automatic Chemiluminescence Immunoassay System Analyzer Bki1100
  • High Quality Automatic Chemiluminescence Immunoassay System Analyzer Bki1100
    High Quality Automatic Chemiluminescence Immunoassay System Analyzer Bki1100

Find Similar Products

Product Description

High Quality Automatic Chemiluminescence Immunoassay System Analyzer Bki1100
Automatic Chemiluminescence Immunoassay System BKI1100
Product Description

 
High Quality Automatic Chemiluminescence Immunoassay System Analyzer Bki1100

Application:

The chemiluminescence immunoassay system uses magnetic particle separation technology, which uses magnetic particles as antibody carriers, which can be evenly distributed in the liquid phase reaction system, with faster reaction speed and higher efficiency. Using enzymatic chemiluminescence method, the light signal is more stable. A new generation of enzymatic substrates, with higher sensitivity and faster luminescence.

Compared with the international brands, the chemiluminescence immunoassay reagents have good consistency, the coincidence rate can reach more than 95%

Features:

Sample Tray:
Disc design, up to 60 samples loading capacity per batch
The position of sample, standard product and quality control positions can be edited Support emergency function.,

Reagent Tray:
Patented semiconductor refrigeration technology
Up to 30 reagent position on board with refrigeration at 2-8ºC
Up to 30 items can be tested at the same time.
Washing and mixing module:
Three-level cleaning mode, higher cleaning efficiency;
Non-contact mixing to avoid cross-contamination.


 

  
High Quality Automatic Chemiluminescence Immunoassay System Analyzer Bki1100
High Quality Automatic Chemiluminescence Immunoassay System Analyzer Bki1100
High Quality Automatic Chemiluminescence Immunoassay System Analyzer Bki1100
 
Product Parameters
Model BKI1100 BKI2200
Throughput 80T/H 120T/H
Principle Magnetic particle enzymatic chemiluminescence
Modes of Operation Random, Batch and STAT
Separation method Magnetic separation technology
Sample Positions 60 (Each position could be used as an emergency position)
Reagent Positions 30 pcs (2-8ºC refrigeration)
Incubation Positions 50 80
Time to 1st Result 18 Minutes
Sample Volume 15-100μl
Detection Precision CV≤5%
Carry-over Rate ≤10-5
Correlation Coefficient r≥0.99
Calibration Stability 28 Days
Calibration Type 6/7-point calibration
Software system Windows 7/8/10, 32 or 64 bit
Bi-direction, support HL7 protocol
Intuitive User Interface, Intelligent Data Management
Interface TCP/IP Network interface
Other Function Liquid level detection
Anti-collision function
Sample barcode scanning
Reagent radio frequency identification
Intelligent alarm prompt
Power Supply AC110/220V,50/60Hz
External Size (W*D*H) 1120*735*513mm 1305*770*1150mm
Net Weight 130Kg 220Kg
Package Size (WD*H) 1303*873*854mm 1608*898*1534mm
Gross Weight 180kg 294kg

Reagent Menu:

Thyroid

TSH;TT4;TT3;FT4;FT3;TgAb;TPOAb;TG;Anti-TSHR; CT

Anemia

FERRITIN;VB12;FA

Liver Fibrosis

CIV;LN;HA;PIIINP

Hypertension

ALD;ACTH;Cortisol; Renin

Fertility

β-HCG;E2;P;T;PRL;FSH; LH;DHEA-S;SHBG;AMH

Growth

GH

Bone Metabolism

BGP; 25-OH-Vit-D; iPTH;BGP

Tumor Marker

CA125;CA15-3;CA199;AFP;CEA; t-PSA; f-PSA

Pepsinogen

PGI;PGII

Kidney Function

β2-MG

Rheumatism

Anti-CCp

Diabetes

C-P;INS

ardiac Marker

cTnl; CK-MB;MYO; NT-proBNP

lnflammation

PCT;IL-β

One-Stop Shopping

 

High Quality Automatic Chemiluminescence Immunoassay System Analyzer Bki1100High Quality Automatic Chemiluminescence Immunoassay System Analyzer Bki1100

High Quality Automatic Chemiluminescence Immunoassay System Analyzer Bki1100

High Quality Automatic Chemiluminescence Immunoassay System Analyzer Bki1100High Quality Automatic Chemiluminescence Immunoassay System Analyzer Bki1100
 
Company Profile

High Quality Automatic Chemiluminescence Immunoassay System Analyzer Bki1100

High Quality Automatic Chemiluminescence Immunoassay System Analyzer Bki1100
High Quality Automatic Chemiluminescence Immunoassay System Analyzer Bki1100

High Quality Automatic Chemiluminescence Immunoassay System Analyzer Bki1100

High Quality Automatic Chemiluminescence Immunoassay System Analyzer Bki1100

After-sales service

High Quality Automatic Chemiluminescence Immunoassay System Analyzer Bki1100

Customer feedback

High Quality Automatic Chemiluminescence Immunoassay System Analyzer Bki1100High Quality Automatic Chemiluminescence Immunoassay System Analyzer Bki1100

Package&Delivery

High Quality Automatic Chemiluminescence Immunoassay System Analyzer Bki1100

Contact

High Quality Automatic Chemiluminescence Immunoassay System Analyzer Bki1100




 

 



 

About the Supplier

This supplier has been audited by BV. Verify the report on the official BV website with ID "MIC-ASR2551661". Items marked "verified" are certified.

Watch Video
Watch Video
Biobase Biolin Co., Ltd.
Biobase Biolin Co., Ltd.
Biobase Biolin Co., Ltd.
Biobase Biolin Co., Ltd.
Biobase Biolin Co., Ltd.
Biobase Biolin Co., Ltd.
Biobase Biolin Co., Ltd.
Biobase Biolin Co., Ltd.

About Our Factory & Business Background

verified Business Type
Manufacturer/Factory & Trading Company
Address
2# Building, No. 9 Gangxing Road, High-Tech Zone, Jinan, Shandong, China
verified Plant Area
29260 square meters
verified Number of Employees
150
verified Registered Capital
10,000,000 RMB
verified Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment
verified International Commercial Terms(Incoterms)
FOB, CIF, CFR, EXW
verified Average Lead Time
Peak Season Lead Time: one month
Off Season Lead Time: one month
verified Nearest Port
Qingdao Port
verified Minimum Order Quantity
1 Set
verified Supply Chain Partners
6

Our Production Capability & Technical Expertise

verified Main Products
Laboratory Equipment, Medical Device, Biochemistry Analyzer, Autoclave, Biological Safety Cabinet, Laminar Flow Cabinet, Fume Hood, Centrifuge, Oven, Incubator
verified Production Lines
8
verified Production Machines
Bending machine, Laser cutting machine
verified QA/QC inspectors
8 people
verified Inspection Type for Finished Products
100% inspection(Visual inspection & Function inspection)
verified Inspection Method for Finished Products
Have instructions and uniformly followed
verified Customization Options
Customization from Samples, Customization from Designs, Full Customization, Minor Customization, Flexible customization
verified ODM Service Available
Yes
verified OEM Service Available
Yes
verified R&D Engineers
15 people
verified Traceability of Raw Materials
Yes

Our Industry Experience & Global Business Record

verified Year of Establishment
2017-02-09
verified Export Year
8.5 Years
verified Main Markets
North America, South America, Europe, Southeast Asia/ Mideast, Africa, East Asia(Japan/ South Korea), Australia
verified Repeat Buyers Choice
50%~80%
verified Number of Foreign Trading Staff
29
verified Overseas Agent/Branch
Yes
verified New Products Launched in Last year
Yes

Our Certifications, Standards & Industry Recognition

verified Cooperated with Fortune 500
No

FAQ

What is the throughput of the BKI1100?
The system has a throughput of 80 tests per hour.
How long does it take to get the first result?
The time to the first result is 18 minutes.
What is the sample capacity?
It supports up to 60 sample positions, which can also serve as emergency positions.
What is the detection precision?
The detection precision (CV) is less than or equal to 5%.
Does the system support customization?
Yes, we offer full, minor, and flexible customization from samples or designs.
What is the minimum order quantity?
The minimum order quantity is 1 set.
What are the payment terms?
We accept LC, T/T, D/P, PayPal, Western Union, and small-amount payments.