• Biobase Portable pH Conductivity/TDS/Salinity Meter Endpoint pH Meter
  • Biobase Portable pH Conductivity/TDS/Salinity Meter Endpoint pH Meter
  • Biobase Portable pH Conductivity/TDS/Salinity Meter Endpoint pH Meter
  • Biobase Portable pH Conductivity/TDS/Salinity Meter Endpoint pH Meter
  • Biobase Portable pH Conductivity/TDS/Salinity Meter Endpoint pH Meter
  • Biobase Portable pH Conductivity/TDS/Salinity Meter Endpoint pH Meter

Biobase Portable pH Conductivity/TDS/Salinity Meter Endpoint pH Meter

After-sales Service: Yes
Warranty: 1 Year
Display: Digital
Portable: Portable
Appliance: Food Analysis, Medical Research, Biochemistry
Certification: /
Customization:
Trading Company

360° Virtual Tour

Diamond Member Since 2022

Suppliers with verified business licenses

Shandong, China
Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Multi-language Pioneer
5 languages freely used by foreign trade staff. include: English, French, Russian, Arabic, Spanish
Experienced Team
The supplier has 10 foreign trading staff(s) and 7 staff(s) with over 6 years of overseas trading experience
to see all verified strength labels (13)
  • Overview
  • Product Description
  • Product Parameters
  • Company Profile
  • Contact us
Overview

Basic Info.

Model NO.
PH-530
Calibration Points
1-3 Points
Normalization Temperature
25
Dimensions
170*85*30mm
Gross Weight
2kg
Transport Package
Carton or Wooden Package
Specification
325*124*270mm
Trademark
BIOBASE
Origin
China
HS Code
9027899090
Production Capacity
50000

Product Description

Biobase Portable pH Conductivity/TDS/Salinity Meter Endpoint pH Meter

Product Description

Biobase Portable pH Conductivity/TDS/Salinity Meter Endpoint pH Meter
Biobase Portable pH Conductivity/TDS/Salinity Meter Endpoint pH Meter
Features:
* 1 to 5 points calibration with automatic calibration solution recognition.
* Selectable cell constant ( 0.1/1/10 ), normalization temperature.( 20°C or 25°C )
* TDS conversion factor, seawater and practical salinity measurement modes.
* Linear orpure water compensation improves the measurement accuracy.
* Automatic T emperature Compens ation ensures accurate reading.
* Calibration Due Reminder prompts user to calibrate the meter regularly.
* Stability indicator automatically shows current measurement status.
* Auto-Hold function freezes stable measured value for easy viewing and recording.
* Selectable temperature unit(ºC orºF) meets different application requirements.
* Automatic electrode diagnosis shows cell constant of the conductivity electrode.
* Help message as a operational guide that helps you quickly begin using the meter.
* System menu allows setting the 11 parameters, including the temperature unit, number of calibration points, stability condition, etc.
* Reset feature automatically resumes parameters back to factory default options.
* Expanded memory stores and recalls up to 500 readings.
* Built-in real-time clock stamps stored data to meet GLP standard.
* Stored data can be transferred into computer by USB communication interface.

Accessories:
Conductivity electrode, temperature probe, conductivity standard solutions(84μS/cm, 1413μS/cm, 12.88mS/cm), batteries
and carrying case.

 

Product Parameters

Model
PH-520
PH-530
PH-531
PH-540
Conductivity Range
0-20.00, 200.0, 2000S/cm, 20.00, 200.0mS/cm
Conductivity Accuracy
±0.5% F.S
TDS Range
/
0~100ppt (Max. 200ppt, depending on factor setting)
/
0~100ppt (Max. 200ppt, depending on factor setting)
TDS Accuracy
/
±1%F.S
/
±1%F.S
Salinity Range
/
0-1 Oppt (Max. 80ppt)
Salinity Accuracy
/
±1%F.S
Resistivity Range
/
0-100MQ
Resistivity Accuracy
/
±1% F.S
Calibration Points
1-3 points (Model 520A), 1-5 points (Model 530/531/540)
Calibration Solutions
10S/cm, 84pS/cm, 1413pS/cm, 12.88mS/cm, 111.8mS/cm
Temperature Compensation
0~100°C, 32~212°F, Manual or Automatic
Temperature Coefficient
0.0-10.0%/°C
Normalization Temperature
25°C (Model 520A), 20°C or 25°C (Model 530/531/540)
Cell Constant
K=0.1,1,10 or User-defined
Memory
Stores up to 500 data sets, USB Communication Interface
Power Requirements
3M.5V "AA" batteries (Standard) or DC5V power adapter (Optional)
Dimensions
170*85*30mm
Package Size(W*D*H)
475*155*350mm
Net Weight
300g
Gross Weight
2kg

 

Company Profile

Biobase Portable pH Conductivity/TDS/Salinity Meter Endpoint pH MeterBiobase Portable pH Conductivity/TDS/Salinity Meter Endpoint pH MeterBiobase Portable pH Conductivity/TDS/Salinity Meter Endpoint pH MeterBiobase Portable pH Conductivity/TDS/Salinity Meter Endpoint pH MeterBiobase Portable pH Conductivity/TDS/Salinity Meter Endpoint pH Meter

Biobase Portable pH Conductivity/TDS/Salinity Meter Endpoint pH Meter

Biobase Portable pH Conductivity/TDS/Salinity Meter Endpoint pH Meter

Biobase Portable pH Conductivity/TDS/Salinity Meter Endpoint pH Meter
Biobase Portable pH Conductivity/TDS/Salinity Meter Endpoint pH Meter

Contact us

Biobase Portable pH Conductivity/TDS/Salinity Meter Endpoint pH Meter

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

360° Virtual Tour

Diamond Member Since 2022

Suppliers with verified business licenses

Trading Company
Number of Employees
15
Year of Establishment
2017-02-09